Orion-system VCM-X E-BUS Component Manual do Utilizador Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 128
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 22
VCM-X Component & Systems Wiring
Interconnected System
23
FILENAME
DESCRIPTION:
PAGE
Wiring & Connection Diagram
JOB NAME
O-VCMX-Sys-InterConnect-1A.CDR
VCM-X E-BUS Interconnected System
1 of 1
Typical Interconnected System
Connect To Modular
I/O Connectors
Located On Back
Of The System Manager
Connect MIni Din
Connector
Cable Ends To Female
Connectors on
Modular Service Tool
And VCM-X Controller
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
STATUS
SETPOINTS
SCHEDULES
ALARMS
OVERRIDES
Line Voltage
Modular Service
Tool SD
Modular System Manager SD
(Front Side Shown)
System Manager TS II
(Back Side Shown)
24 VAC
(6 VA)
Note: Either A Modular System
Manager SD, System Manager TS
II, Modular Service Tool SD Or PC
With Prism 2 Software Installed
Can Be Used To Program And
Configure The Orion System. For
Computer & Remote Connection
Information, See The Computer
Connection Section Of This
Manual.
Line Voltage
VCM-X E-BUS Unit Controller
24 VAC
(8 VA)
SHLD
T
R
Typical Terminal Blocks. All
Wiring To Be T To T, SHLD (G)
To SHLD (G) & R To R
T
G
R
485 LOOP
WARNING
OBSERVE
POLARITY
RS T +
BLACK (R)
Connect To
T, R & S
Terminals On
VCM-X
Controller
RED (24 VAC)
BROWN (GND)
WHITE (T)
BARE (S)
.1uF
YS102178 R4
WQVGAGraphical Interface
WattMaster Controls, Inc
C24
R9
R7
R6
R5
R2
R1
C51
C39
C20
C19
C15
C14
C13
C12
C11
C10
C9
C7
C1
X3
8.00Mhz
OFF
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002 1002
1002 1002
1002
1002
1002 1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
1002
.1uF
1002
1002
.1uF
.1uF
.1uF
.1uF
LTC3824
1002
1002
1002
1002
1002
1002
66.000Mhz
MADE IN USA
330uF 50V 330uF
1002
SERIAL #
OPT4
OPT3
OPT2
OPT1
TERM
RTC
YS102178 R4
WQVGAGraphical Interface
WattMaster Controls, Inc
CAL
5V 3.3V 2.5V
J3
R34 R16
R13R8
R39
X2
R26
R17
R14
C24
U13
R49
R48
R47
R46
R45
R44
R43
R40
R37
R35
R32R31
R29
R27
R24
R22
R12
R11
R10
R9
R7
R6
R5
R2
R1
L5
L4
D12
D11
D1
C51
C50
C45
C41
C39
C36
C20
C19
C18
C17
C16
C15
C14
C13
C12
C11
C10
C9
C8
C7
C6
C5 C4
C1
J1
R41
C23
C25
C26
R42
X3
R20
C27
C34 C40
U10
U11
C28
C29
R18
C35
D2
L1
R25
C31
R19
U9
R28
C32 R30
R33
C30
R15
Q2
R21
R23
SW1
C2C3
V1
R36
1002
RS T +
1002
R
T
5V
GND
TERM
For Stand Alone Applications
Both Jumpers Must Be ON
WHITE (T)
DRAIN WIRE (SHLD)
BLACK (R)
RED (24 VAC)
Line Voltage
24 VAC
(6 VA)
CLEAR (GND)
GREEN (GND)
To Next HVAC Unit
Controller On Loop
Up To 60 Controllers
Can Be Interconnected
Line VoltageLine Voltage
VCM-X E-BUS Unit Controller
VCM-X E-BUS Unit Controller
24 VAC
(8 VA)
24 VAC
(8 VA)
WARNING
OBSERVE
POLARITY
WARNING
OBSERVE
POLARITY
BY:
S. Olson
DATE:
05/12/15
Figure 4: Interconnected System Wiring
Vista de página 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 127 128

Comentários a estes Manuais

Sem comentários