RNE CONFIGURATION
VCM-X / RNE Operator Interface SD
34
RNE Con guration Screen Index
RNE Con guration Screen Index
NOTE: For VCM-X Con guration Screens, see page 24.
The available Con guration Screens for the RNE Controller are listed
on the next few pages by sequential screen number. When each RNE
Controller is con gured for the rst time, it is best to start with screen
#1 and proceed to each screen in numerical order until you have viewed
all available Con guration Screens. This ensures that you have seen all
the available RNE Controller con guration possibilities and have the
opportunity to change or accept the defaults for each screen.
Once the unit is con gured and you decide to change one of the screen
options, it is helpful to know what screen number contains the con gu-
ration you wish to change. With this in mind, the following is a list of
all the RNE Controller Con guration Screens in numerical order with
a brief listing of the con guration feature available on each screen.
Screen #1 Duct Static Pressure Control
Screen #2 Supply Fan Cycle Mode
Screen #3 HVAC Mode Enable
Screen #4 HVAC Reset Source
Screen #5 Reset Interval Rate
Screen #6 Dehumidi cation Control
Screen #7 Dehumidi cation Priority
Screen #8 Dehumidi cation Unoccupied
Screen #9 Outdoor Humidity Sensor
Screen #10 Indoor Humidity Sensor
Screen #11 Heat During Dehumidify
Screen #12 Economizer Control
Screen #13 Title 24 Economizer
Screen #14 Proof of Flow Input
Screen #15 Modulating Heating
Screen #16 Modulating Heat Output Signal
Screen #17 Modulating Heat Reverse Acting
Screen #18 Modulating Heat Proportional Window
Screen #19 Modulating Cooling Type
Screen #20 RNE Tonnage
Screen #21 Water Source Heat Pump Installed
Screen #22 Modulating Cooling Reverse Acting
Screen #23 Modulating Cool Proportional Window
Screen #24 Head Pressure Module Installed
Screen #25 Type of Head Pressure Module: 1 or 2
Condenser
Screen #26 Air ow Monitoring Station
Screen #27 Monitor Outdoor Air CFM
Screen #28 Control Outdoor Air CFM
Screen #29 Outdoor Duct/Damper Size
Screen #30 Monitor Return Air CFM
Screen #31 Return Duct/Damper Size
Screen #32 Monitor Supply Air CFM
Screen #33 Supply Duct/Damper Size
Screen #34 CO
2
Sensor Output Signal
Screen #35 CO
2
Sensor Maximum Scale
Screen #36 Building Pressure Modulating Control
Screen #37 Building Pressure Reverse Acting
Screen #38 Building Pressure Output Signal
Screen #39 Air to Air Heat Pump Control
Screen #40 Reversing Valve Active For Heat/Cool
Screen #41 Emergency Shutdown Input
Screen #42 Return Air Bypass Control
Screen #43 Broadcast Outdoor Temperature
Screen #44 Broadcast Outdoor Humidity
Screen #45 Broadcast Supply Temperature
Screen #46 Broadcast Status Fan & Heat
Screen #47 Broadcast Internal Time Clock
Screen #48 Broadcast Internal Schedule
Screen #49 Broadcast VAV Boxes Force to Max
Screen #50 Broadcast VAV Boxes Force to Fixed
Screen #51 1 HVAC Unit w/Boxes on Multiple Loops
Screen #52 Unit Uses R410A Refrigerant
Screen #53 Main Fan Maximum Voltage
Screens #54-57 Cooling & Heating Staging Delays
Screens #58-77 Relay Con guration Screens