Orion-system VAV II Controller v.1 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Hardware Orion-system VAV II Controller v.1. Orion System VAV II Controller v.1 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 80
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
VAV/CAV/MUA II Controller
Operator Interface SD
Technical Guide
VAV/CAV Controller Code: SS1003
MUA II Controller Code: SS1004
VAV/Zone Controller Code: SS1001, SS1005, SS1025
Requires Modular Service Tool SD Code: SS1063
Requires Modular System Manager SD Code: SS1064
www.orioncontrols.com
Vista de página 0
1 2 3 4 5 6 ... 79 80

Resumo do Conteúdo

Página 1 - Technical Guide

VAV/CAV/MUA II ControllerOperator Interface SD Technical GuideVAV/CAV Controller Code: SS1003MUA II Controller Code: SS1004VAV/Zone Controller Code:

Página 2 - IMPORTANT NOTICE

MODULAR SERVICE TOOL SD VAV/CAV/MUA Operator Interface SD10Modular Service Tool KeysOperator InterfacesIn order to confi gure and program the Orion Sy

Página 3

VAV/CAV/MUA Operator Interface SD MODULAR SERVICE TOOL SD11Modular Service Tool InitializationModular Service Tool Initialization Scree

Página 4 - Modular Service Tool SD

MODULAR SERVICE TOOL SD VAV/CAV/MUA Operator Interface SD12Setting the Operating ModeThe Operating Mode is displayed on the last line of the Main Scr

Página 5

VAV/CAV/MUA Operator Interface SD MODULAR SERVICE TOOL SD13Modular Service Tool Alarm SearchNOTE: When you press the <ALARMS> but

Página 6 - Modular System Manager SD

MODULAR SERVICE TOOL SD VAV/CAV/MUA Operator Interface SD14The screens will step through the Start Time and then the Stop Time for each day of the we

Página 7 - Back View

VAV/CAV/MUA Operator Interface SD MODULAR SERVICE TOOL SD15 Holiday Start/Stop TimesVAV/CAV/MUA Hldy Holiday Schedule Start Event #1: XX

Página 8 - Power/Comm Board Wiring

ZoneZoneMODULAR SYSTEM MANAGER SD VAV/CAV/MUA Operator Interface SD16System Manager SD Keys and ButtonsOperator InterfacesIn order to confi gure and

Página 9 - Stand Alone Connection

VAV/CAV/MUA Operator Interface SD MODULAR SYSTEM MANAGER SD17System Manager SD InitializationSystem Manager SD Initialization ScreenAfter conn

Página 10 - Modular Service Tool Keys

ZoneZoneMODULAR SYSTEM MANAGER SD VAV/CAV/MUA Operator Interface SD18Setting the Operating ModeSetting the Operating ModeThe Operating Mode is displ

Página 11 - NEXT) More Options

VAV/CAV/MUA Operator Interface SD MODULAR SYSTEM MANAGER SD19Changing PasscodesSystem Manager PasscodesChanging the mode of operation, updating

Página 12

SD CARD UPDATING INSTRUCTIONSThe Modular Service Tool and Modular System Manager are equipped with an SD memory card. This SD card can be removed and

Página 13 - Alarm and Override Search

ZoneZoneMODULAR SYSTEM MANAGER SD VAV/CAV/MUA Operator Interface SD20Network Mode & Multiple Managers Loop SearchWhen the System Manager is co

Página 14 - Schedules and Holidays

VAV/CAV/MUA Operator Interface SD MODULAR SYSTEM MANAGER SD21 Unit Alarm Search and Override SearchAlarm ScreenNO ALARMS DETECTEDTo check control

Página 15 - <1> to run continu

ZoneZoneMODULAR SYSTEM MANAGER SD VAV/CAV/MUA Operator Interface SD22 Week SchedulesFrom the Unit Schedule Menu, select Week Schedules. The follow

Página 16 -

VAV/CAV/MUA Operator Interface SD MODULAR SYSTEM MANAGER SD23 Holiday Start/Stop Day SelectionFrom the Unit Schedule Menu, select Holiday Sche

Página 17 - Programming the Date

ZoneZoneVAV/CAV CONTROLLER CONFIGURATION VAV/CAV/MUA Operator Interface SD24VAV/CAV Confi guration Screen Index VAV/CAV Confi guration Screen IndexT

Página 18 - Setting the Operating Mode

VAV/CAV/MUA Operator Interface SD VAV/CAV CONTROLLER CONFIGURATION25 Confi guration ScreensIn order to correctly set up the Unit Controller, you must

Página 19

ZoneZoneVAV/CAV CONTROLLER CONFIGURATION VAV/CAV/MUA Operator Interface SD26VAV/CAV Confi guration Screens Confi guration Screen #3 - Economizer C

Página 20

VAV/CAV/MUA Operator Interface SD VAV/CAV CONTROLLER CONFIGURATION27VAV/CAV Confi guration ScreensConfi guration Screen #10 - Supply Air Setpoint Rese

Página 21

ZoneZoneVAV/CAV CONTROLLER CONFIGURATION VAV/CAV/MUA Operator Interface SD28VAV/CAV Confi guration ScreensConfi guration Screen #16 - Broadcast Sup

Página 22

VAV/CAV/MUA Operator Interface SD VAV/CAV CONTROLLER SETPOINTS29Confi guration Screens #22-41 - RelayConfi guration Screens VAV/CAV Cnfg ID 0

Página 23 - Schedule Override

TABLE OF CONTENTSOVERVIEW & SYSTEM CONNECTION ...

Página 24

VAV/CAV CONTROLLER SETPOINTS VAV/CAV/MUA Operator Interface SD30 Setpoint Screen IndexThe available Setpoint Screens for the VAV/CAV Controller are

Página 25 - VAV/CAV Confi guration Screens

VAV/CAV/MUA Operator Interface SD VAV/CAV CONTROLLER SETPOINTS31VAV/CAV Setpoint ScreensSetpoints - General Procedures Modular Service Tool

Página 26

VAV/CAV CONTROLLER SETPOINTS VAV/CAV/MUA Operator Interface SD32Description Minimum Default MaximumSAT Heating Spt 60ºF 140ºF 200ºFReset Limit Spt

Página 27

VAV/CAV/MUA Operator Interface SD VAV/CAV CONTROLLER SETPOINTS33If the Outdoor Air Temperature drops below the Cooling Lockout set- point by

Página 28

VAV/CAV CONTROLLER SETPOINTS VAV/CAV/MUA Operator Interface SD34Setpoint Screen #14 - Economizer Minimum Position & Control Rate VAV/CAV Spt

Página 29

VAV/CAV/MUA Operator Interface SD VAV/CAV CONTROLLER SETPOINTS35Setpoint Screen #21 - HVAC ScheduleVAV/CAV Spts ID 0001 AHU Schedule By Sch

Página 30 - VAV/CAV Setpoint Screen Index

VAV/CAV CONTROLLER SETPOINTS VAV/CAV/MUA Operator Interface SD36Setpoint Screen #24 - Push-Button Override DurationVAV/CAV Spts ID 0001 Push-Butt

Página 31 - VAV/CAV Setpoint Screens

VAV/CAV/MUA Operator Interface SD VAV/CAV CONTROLLER SETPOINTS37Confi guration Screen #28- #31 - Cool/Heat Stage Delays VAV/CAV Spts ID 0001

Página 32

VAV/CAV CONTROLLER STATUSVAV/CAV/MUA Operator Interface SD 38Status Screen InstructionsFrom any menu screen, press <STATUS>. The Unit Selection

Página 33

VAV/CAV CONTROLLER STATUSVAV/CAV/MUA Operator Interface SD 39VAV/CAV Status ScreensStatus Screen 1 - ModeVAV/CAV v 1.00 0001Occupied Mode

Página 34

ZoneZoneSYSTEM CONNECTIONVAV/CAV/MUA Operator Interface SD4Modular Service Tool SD Modular Service Tool SDModeSelection6547081329-10.00”4.75”2.02"

Página 35

VAV/CAV CONTROLLER STATUSVAV/CAV/MUA Operator Interface SD 40VAV/CAV Status ScreensStatus Screen 5 - Outdoor Air Temperature & HumidistatVAV/C

Página 36

VAV/CAV CONTROLLER STATUSVAV/CAV/MUA Operator Interface SD 41VAV/CAV Status ScreensStatus Screen 9 - MODGAS Output % & MHGRV Output

Página 37

ZoneZoneMUA II CONTROLLER CONFIGURATION VAV/CAV/MUA Operator Interface SD42MUA II Confi guration Screen Index MUA II Confi guration Screen IndexThe a

Página 38 - VAV/CAV Status Screen Index

VAV/CAV/MUA Operator Interface SD MUA II CONTROLLER CONFIGURATION43 Confi guration ScreensIn order to correctly set up the Unit Controller, you must fi

Página 39 - VAV/CAV Status Screens

ZoneZoneMUA II CONTROLLER CONFIGURATION VAV/CAV/MUA Operator Interface SD44Confi guration Screen #7 - Broadcast Humidity Reading MUA-II Cnfg 00

Página 40

VAV/CAV/MUA Operator Interface SDMUA II CONTROLLER SETPOINTS45MUA II Setpoint Screen Index Setpoints - General ProceduresModular Service Tool Instruct

Página 41

MUA II CONTROLLER SETPOINTSVAV/CAV/MUA Operator Interface SD46MUA II Setpoint ScreensSetpoint Screen #1 - Supply Air Temperature SetpointMUA II SP

Página 42

VAV/CAV/MUA Operator Interface SDMUA II CONTROLLER SETPOINTS47Setpoint Screen #9 - Set Supply Air Temperature ResetMUA II SPTS 0001 Set SAT Temp

Página 43 - MUA II Confi guration Screens

MUA II CONTROLLER SETPOINTSVAV/CAV/MUA Operator Interface SD48Both the Heating Stages and the DX Cooling Stages utilize Staging Up and Down Delay Per

Página 44

VAV/CAV/MUA Operator Interface SDMUA II CONTROLLER SETPOINTS49The Push-Button Override Duration Setpoint allows you to adjust the amount of time the O

Página 45 - MUA II Setpoint Screen Index

VAV/CAV/MUA Operator Interface SD SYSTEM CONNECTION5Modular Service Tool SDWhether you have a Stand Alone, Interconnected, or Networked

Página 46 - MUA II Setpoint Screens

ZoneZoneMUA II CONTROLLER STATUS VAV/CAV/MUA Operator Interface SD50MUA II Controller Status Screen IndexStatus Screen InstructionsFrom any menu scre

Página 47

VAV/CAV/MUA Operator Interface SD MUA II CONTROLLER STATUS51MUA II Status ScreensStatusThe MUA Controller Status Screens are accessed by pressing th

Página 48

ZoneZoneMUA II CONTROLLER STATUS VAV/CAV/MUA Operator Interface SD52MUA II Status ScreensStatus Screen 6 - Current Reset Temperature & Humidit

Página 49

VAV/ZONE CONTROLLER PROGRAMMINGVAV/CAV/MUA Operator Interface SD53VAV/Zone Confi guration Screens VAV Zone Confi gurationIn order to correctly

Página 50 - MUA II CONTROLLER STATUS

VAV/ZONE CONTROLLER PROGRAMMING VAV/CAV/MUA Operator Interface SD54VAV/Zone Confi guration Screens Confi guration Screen #3 - Voting ZoneXX Box Cnfg

Página 51 - MUA II Status Screens

VAV/ZONE CONTROLLER PROGRAMMINGVAV/CAV/MUA Operator Interface SD55VAV/Zone Confi guration ScreensConfi guration Screen #10 - Dump ZoneXX Box Cn

Página 52

VAV/ZONE CONTROLLER PROGRAMMING VAV/CAV/MUA Operator Interface SD56VAV/Zone Setpoint Screens VAV/Zone Controller SetpointsModular Service Tool Instruc

Página 53

VAV/ZONE CONTROLLER PROGRAMMINGVAV/CAV/MUA Operator Interface SD57Setpoint Screen #3 - AHU Heat Call Space TempXX Box Spts IDXXXXAHU Heat Ca

Página 54 - <0> if you

VAV/ZONE CONTROLLER PROGRAMMING VAV/CAV/MUA Operator Interface SD58VAV/Zone Setpoint Screens Setpoint Screen #8 - Damper Airfl ow Night Min and

Página 55 - Separate Loop

VAV/ZONE CONTROLLER PROGRAMMINGVAV/CAV/MUA Operator Interface SD59Description Minimum Default MaximumOut of Limits 1 Min 30 Min 300 MinSetpoint

Página 56 - VAV/Zone Setpoint Screens

ZoneZoneSYSTEM CONNECTIONVAV/CAV/MUA Operator Interface SD6Modular System Manager SD Modular System Manager SDENTERCLEARESCPREVNEXTDOWNUP654DEC708132

Página 57

ZoneZoneVAV/ZONE CONTROLLER STATUS VAV/CAV/MUA Operator Interface SD60 VAV/Zone StatusStatus Screen #1 - Mode of OperationXX Box v4.01 IDXXXXOccup

Página 58

VAV/CAV/MUA Operator Interface SD VAV/ZONE DAMPER FORCE61Status Screen #5 - Zone Damper Position, Airfl ow, and Desired CFMXX Box

Página 59

VAV/ZONE DAMPER FORCE VAV/CAV/MUA Operator Interface SD62VAV/Zone Damper Force Modes Damper Force ModesDamper Force Modes are available for testing o

Página 60 - VAV/Zone Status Screens

MINILINK PD PROGRAMMINGVAV/CAV/MUA Operator Interface SD 63MiniLink PD Confi guration Screens MiniLink PD Confi gurationIn order to correctly setup

Página 61

ZoneZoneMINILINK PD STATUS VAV/CAV/MUA Operator Interface SD64MiniLink PD Confi guration & Status ScreensConfi guration Screen #4 - Optimal StartT

Página 62 - VAV/Zone Damper Force Modes

TROUBLESHOOTING65VAV/CAV/MUA Operator Interface SDVAV/CAV/MUA II Outputs Force Outputs ForceOutputs Force settings are available for

Página 63 - MINILINK PD PROGRAMMING

APPENDIX A - SAVE, LOAD, COPY SETPOINTS VAV/CAV/MUA Operator Interface SD66Modular Service Tool InstructionsFrom any menu screen, press <BALANCE-

Página 64 - MINILINK PD STATUS

VAV/CAV/MUA Operator Interface SDAPPENDIX A - SAVE, LOAD, COPY SETPOINTS67 Copy Setpoints - Network ModeTo copy a saved setpoints fi le to other contro

Página 65 - VAV/CAV/MUA II Outputs Force

APPENDIX B - UPDATING THE SD CARD VAV/CAV/MUA Operator Interface SD68Updating Your SD Memory CardYou may need to update your SD memory card from tim

Página 66

APPENDIX C - UPDATING CONTROLLERS & E-BUS MODULES 69VAV/CAV/MUA Operator Interface SDUpdating Software Using the Modular Service Tool SDTo updat

Página 67

VAV/CAV/MUA Operator Interface SD SYSTEM CONNECTION7Modular System Manager SD Network Connection Network ConnectionAs previously descri

Página 68 - SD Memory Card Update

APPENDIX C - UPDATING CONTROLLERS & E-BUS MODULES 70 VAV/CAV/MUA Operator Interface SDUpdating Controller & E-BUS Module SoftwareE-BUS Mo

Página 69 - WattMaster Controllers

VAV/CAV/MUA Operator Interface SD INDEX71A-C24-Hour Military Format...14,221111...192222...19

Página 70 - E-BUS Modules

INDEX VAV/CAV/MUA Operator Interface SD72D-HDDamper Airfl owCool/Heat Minimum...57Fan On Min...58Fixed Position...58Integral...

Página 71

VAV/CAV/MUA Operator Interface SD INDEX73H-MHVAC ModeCooling Setpoints...31Heating Setpoints...31Sc

Página 72

INDEX VAV/CAV/MUA Operator Interface SD74N-SNNetwork Connection, Modular System Manager...7Night Minimum Damper Airfl ow...58OOAT Sensor

Página 73 - VAV/Zone...59

VAV/CAV/MUA Operator Interface SD INDEX75SSAT Reset Offset...32SAT Sensor Calibration...49ScheduleB

Página 74 - T...32

INDEX VAV/CAV/MUA Operator Interface SD76S-VSensor CalibrationSpace Temperature...59Supply Air Temperature...59Sensor Calibration for O

Página 75

VAV/CAV/MUA Operator Interface SD INDEX77V-ZVAV/ZoneAHU Heat Call Space Temperature...57Box Heat Allow...

Página 76 - , VAV/Zone Status...60

NOTESVAV/CAV/MUA Operator Interface SD78

Página 77

NOTESVAV/CAV/MUA Operator Interface SD79

Página 78

ZoneZoneSYSTEM CONNECTIONVAV/CAV/MUA Operator Interface SD8Power/Comm Board Wiring Figure 5: Typical Power/Comm Board WiringA Power/CommOfUsing. Yo

Página 79

Form: OR-VAVCAVMUAIIOISD-TGD-01C Printed in the USA November 2013All rights reserved. Copyright 2013Wat

Página 80

VAV/CAV/MUA Operator Interface SD SYSTEM CONNECTION9 Stand Alone ConnectionUse Supplied Modular CableWith Stripped Ends ForConnection To

Comentários a estes Manuais

Sem comentários